New Design Smart Network Wiegand TCP/IP Access Control Board with Alarm Interfaces

Product Details
Customization: Available
Type: Access Control Board
Card Type: CPU, HID, Mifare, EM, IC/ID
Still deciding? Get samples of US$ 114/Piece
Request Sample
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
500000 RMB
Plant Area
101~500 square meters
  • New Design Smart Network Wiegand TCP/IP Access Control Board with Alarm Interfaces
  • New Design Smart Network Wiegand TCP/IP Access Control Board with Alarm Interfaces
  • New Design Smart Network Wiegand TCP/IP Access Control Board with Alarm Interfaces
  • New Design Smart Network Wiegand TCP/IP Access Control Board with Alarm Interfaces
  • New Design Smart Network Wiegand TCP/IP Access Control Board with Alarm Interfaces
  • New Design Smart Network Wiegand TCP/IP Access Control Board with Alarm Interfaces
Find Similar Products

Basic Info.

Model NO.
NS-T2/4net. access control board
Interface
USB
Reading Distance
100m
Application
Parking, Hospital, Library, Company, Bank, Store, Office
Communication
TCP/IP 10m/100m Adaptive(Extension RS485)
Input Format of Reader
Wiegand2634(All Card Reader with Compatible Protoc
Number of Inputs
16ea(4 Exit Button, 4 Door Sensor, 4 Wiegand
Number of Outputs
5 Form-C Relay Output(4 Lock, 1 Alarm)
Max Distance From Reader to Controller
100m (Suggestion Distance 80m)
Collocations
PCB Board, Case, Power, Power Line, Serial Port Co
Operation Humidity
10-90%Rh, No Condensation
Max Q ′ Ty of Controller
No Limit
Q ′ Ty of Users
20, 000 Users
Q ′ Ty of Event Buffers(Offline)
70, 000 Event Buffers
Quantity of Readers
4 PCS
Size of PCB Board
L273xw175xh72mm
Transport Package
Neutral Packing
Specification
CE
Trademark
Nordson
Origin
Guangdong
HS Code
123456
Production Capacity
10000PCS/Per Month

Product Description

NEW design smart network wiegand TCP/IP access control board with alarm interfaces

New Design Smart Network Wiegand TCP/IP Access Control Board with Alarm Interfaces
New Design Smart Network Wiegand TCP/IP Access Control Board with Alarm Interfaces
New Design Smart Network Wiegand TCP/IP Access Control Board with Alarm Interfaces

Overview:
NS-T2/4 is a network access control board with new Industrial standard design , All chips use famous brand manufacturers. It Supports TCP/IP and Extension RS485communication.
Multi-function interfaces are reserved for customers, and a variety of event linkage mechanisms are added in the design, such as swiping card, illegal card, alarm input and other events linkage, such as illegal card alarm, alarm linkage door opening and so on.
Multi-wiegand interface input, RFID card or bidirectional access can be realized, the controller has a strong access control function, can provide a perfect single door access control management.
Realize multi-card opening, password opening, card and password opening and different opening modes in different time.
Nordson multi-door networking access controller, strict production management, bring excellent quality, excellent performance has been widely recognized by many large access control system engineering and card system.
(single or double door TCP/IP communication network type multi-door controller also called multi-door network controller, TCP/IP network type multi-door controller and so on.)

Function:
1. Standard TCP/IP communication, multi-level lightning protection and surge protection
2. Large-capacity FLASH, multi-type circuit design optimization, 10 years of continuous power storage data
3. Input/output protection, components from well-known IC manufacturers
4. Various ways to identify and open the door: card, password, card + password, double card, free access, timing door switch and timing alarm
5. Linkage function of the system: the product has reserved abundant interfaces for customers, and a variety of event linkage mechanisms have been added in the design, which can link other events, such as illegal card alarm and alarm linkage door opening, through swiping, illegal card, alarm input and other events.
6. Perfect access control management
The controller has powerful access control function and can provide perfect management of single door access control.
Realize multi-card opening, password opening, card and password opening and different opening modes in different time periods.
First Card
Multi-card Open
Anti-passback
Remote Control
Multi-door interlock
Threaten Code
Normal Open Automatically
7. Powerful Software
When access controller series work with Anson software, it can achieve more complex security function. Such as, access data search, employee shift, attendance statistics.
Access Control and video device linkage
Attendance
On-line access control
Real-time Remote monitoring

Specification
Parameter Single or Two-door Access Control Board Two or Four-Door Access Control Board
Model # NS-T1/T2.net NS-T2/T4.net
Communication TCP/IP 10M/100M adaptive(Extension RS485)
Size of PCB board L330xW288xH72mm L273xW175xH72mm
Power Supply DC12V/400mA
Power Consumption of Circuit Board Less than 100mA
Input Format of Reader Wiegand2634(All card reader with compatible protocol, such as Motorola , HID , EM ,Mifare one etc)
Quantity of Readers 2 pcs 4 pcs
Door Controled 1/2 pcs 2/4 pcs
Door opening time extending setting 1-600 seconds(adjustable)
Max q ' ty of controller No limit
Operation Temperature -10°C-50°C
Operation Humidity 10-90 % RH , No Condensation
Q ' ty of users 20,000 Users
Q ' ty of Event Buffers(offline) 70,000 event buffers
Number of Inputs 8ea(2 exit button, 2 door sensor,2 Wiegand,2 ALARM ) 16ea(4 exit button, 4 door sensor,4 Wiegand,4 ALARM )
Number of Outputs 3 FORM-C Relay Output(2 LOCK,1 ALARM) 5 FORM-C Relay Output(4 LOCK,1 ALARM)
Max Distance from Reader to Controller 100m (suggestion distance 80m)
Max Distance between Controllers RS232: Communication Distance less than 13m, suggestion distance is 3m or less
RS485: bus line max length 1200m, suggestion length 1000m or less, if expansion device added, the distance could be 3000m
TCP/IP: Depends on net coverage area
Collocations PCB board, case, power, power line, serial port communication line, software, manual, certificate, key(2pcs), carton
Alarm for long time door open, ilegal break in, intimidate Yes
Fire and alarm linkage If no connection with the expansion board, only has software interface alarm, and drive the computer speaker. If connected with expansion board, is able to alarm by hardware, if connected with strengthened expansion board, then is able to Security alarm


New Design Smart Network Wiegand TCP/IP Access Control Board with Alarm Interfaces

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier